Untitled Document
home À̸ÞÀÏ Ä«´Þ·Î±×
 

 Å©°Ôº¸±â

HI 8734 -TDSÃøÁ¤±â

*¼¼°¡Áö ÃøÁ¤¹üÀ§ Áß ¼±ÅÃÇÏ¿© ÃøÁ¤ÇÑ´Ù.
*ÁÖ¹®Çϱâ

 

 

 

  ÃøÁ¤¹üÀ§:         LOW- 0.0 to 199.9 mg/l (ppm)
                    MEDIUM- 0 to 1999 mg/l (ppm)
                    HIGH- 0.00 to 19.99 g/l (ppt)
  ÃÖ¼ÒÃøÁ¤´ÜÀ§:      0.1 mg/l; 1mg/l; 0.01 g/l
  Á¤È®µµ:                ±1% Full Scale
  º¸Á¤:      Manual 32 to 122°F (0 to 50°C) with a ß of 2% per degree °C
  4-Ring ÇÁ·Îºê:    HI 76301W  with 1m cable (included)
  º£Å͸®:          9 volt (alkaline battery) / 100 hours of continuous use
  »ç¿ëȯ°æ:            32 to 122°F (0 to 50°C)
  ¹«°Ô:                    13 oz. (355g)
  ±Ô°Ý:           (7.3 x 3.2 x 1.8") (185 x 82 x 45 mm)

 Å©°Ôº¸±â

HI 993310

*Åä¾çÀÇ EC¿Í ¿°ºÐµµ¸¦ ¹Ù·Î ÃøÁ¤ÇÑ´Ù.
*°ÇÁ¶µÈ ÈëÀ̳ª ³·Àº ECÀÏ ¶§´Â AlarmµîÀÌ ÄÑÁø´Ù.
*ÀÚµ¿¿Âµµ º¸Á¤ÀÌ µÈ´Ù.
*ÁÖ¹®Çϱâ

 

 

¸ðµ¨¸í:

HI 993310
ÃøÁ¤¹üÀ§ 0.00 to 19.99 mS/cm; 0.0 to 1.0 g/L of Salt Activity
ÃÖ¼ÒÃøÁ¤´ÜÀ§ 0.01 mS/cm; 0.1 g/L of Salt Activity
Á¤È®µµ (@20°C/68°F) ±2% F.S. (from 0-15.00 mS/cm, excl. probe error)
º¸Á¤ Æ®¸®¸Ó¸¦ ÀÌ¿ëÇÑ ÇÑÆ÷ÀÎÆ® ¼öµ¿º¸Á¤
¿Âµµº¸Á¤ Automatic from 0 to 50°C with ß of 2% per degree °C
ÇÁ·Îºê HI 76305, amperometric, steel, ATC, 1 m cable (included)
HI 76304, amperometric, 1 m cable (included)
º£Å͸® À¯Çü/¼ö¸í 1 x 9V / ¾à100 ½Ã°£ °è¼Ó»ç¿ë
»ç¿ëȯ°æ 0 to 50°C (32 to 122°F); RH 95%
±Ô°Ý 185 x 82 x 45 mm (7.3 x 3.2 x 1.8")
¹«°Ô 355 g (13 oz.)

     Å©°Ôº¸±â

HI9033

*¹æ¼öÇü, ´ÙÁß ¹üÀ§, ATCÀüµµµµ ¹ÌÅÍ
*´Ü´ÜÇÑ ÄÉÀ̽º°¡ ¿ÜºÎ·ÎºÎÅÍÀÇ Ãæ°ÝÀ¸·ÎºÎÅÍ º¸È£ÇÑ´Ù.
*Å»À̿¼ö¿¡¼­ ¼Ò±Ý¹°±îÁö ÃøÁ¤ÀÌ °¡´ÉÇÏ´Ù.
*ÁÖ¹®Çϱâ

 

 

ÃøÁ¤¹üÀ§:                     0.0 to 199.9 µS/cm
                                 0 to 1999 µS/cm
                                 0.00 to 19.99 mS/cm
                                 0.0 to 199.9 mS/cm
ÃÖ¼ÒÃøÁ¤´ÜÀ§:       0.1 µS/cm 1 µS/cm 0.01 mS/cm 0.1 mS/cm
Á¤È®µµ:                        1% of Full scale
º¸Á¤:                                  ¼öµ¿l
¿Âµµº¸Á¤:                            ÀÚµ¿
4-Ring Probe:                 HI 76302W
»ç¿ë ¿Âµµ:                    32 to 122°F (0 to 50°C)
¹«°Ô:                          3.1 lb (1.4 Kg)
±Ô°Ý:                     7.7 x 3.1 x 2.4" (196 X 80 X 60mm)
 

     Å©°Ôº¸±â

HI9034

*¹æ¼öÇü, ´ÙÁß ¹üÀ§, ATC TDS(ÃÑ¿ëÁ¸°íÇü¹°) ÃøÁ¤±â
*ÁÖ¹®Çϱâ

 

 

ÃøÁ¤¹üÀ§:                  LOW- 0.0 to 199.9 mg/l (ppm)
                           MEDIUM- 0 to 1999 mg/l (ppm)
                           HIGH- 0.00 to 19.99 g/l (ppt)
  ÃÖ¼ÒÃøÁ¤´ÜÀ§:              0.1 mg/l; 1mg/l; 0.01 g/l
  Á¤È®µµ:                        ±1% Full Scale
  º¸Á¤:                Æ®¸®¸Ó¸¦ ÀÌ¿ëÇÑ ¼öµ¿ ÇÑÆ÷ÀÎÆ® º¸Á¤
¿Âµµº¸Á¤: ÀÚµ¿
10 to 50°C with a ß of 2% per degree °C 4-Ring Probe: HI 76302W detachable with 1m cable (included) º£Å͸®: 1 x 9 volt (alkaline battery) ¾à100 ½Ã°£ °è¼Ó »ç¿ë
»ç¿ëȯ°æ: 32 to 122°F (0 to 50°C) ¹«°Ô: 15 oz. (425g ) KIT: 3.1 lbs (1.4Kg) ±Ô°Ý: 7.7 x 3.1 x 2.4" (196 x 80 x 60mm)

 HI 9835

*¹æ¼öÇü EC/TDS/NaCl/°C ÃøÁ¤±â
*ÃøÁ¤µÇ´Â »ùÇÿ¡ µû¶ó ±â±â°¡ ÀÚµ¿À¸·Î ¹üÀ§¸¦ °áÁ¤ÇÏ°í ¾Ë¸ÂÀº ´ÜÀ§¸¦ Ç¥½ÃÇÑ´Ù.
*¿Âµµ´Â Ç×»ó ÃøÁ¤µÇ´Â Ç׸ñ°ú ÇÔ²² µ¿½Ã¿¡ Ç¥½ÃµÈ´Ù.
*Å» À̿¼ö¿¡¼­ ¼Ò±Ý¹°¿¡ À̸£±â±îÁö ¸ðµç »ùÇÿ¡ Àû¿ëÀÌ °¡´ÉÇÏ¸ç ¿ÂµµÀÇ ÀÚµ¿º¸Á¤
  ÀÌ ÀÌ·ç¾îÁø´Ù.
*ÁÖ¹®Çϱâ

 

 

 

EC
(Autoranging)
TDS
(Autoranging)
NaCl Temperature
ÃøÁ¤¹üÀ§ 00.0 ~ 29.99 µS/cm
30.0 ~ 299.9 µS/cm
300 ~ 2999 µS/cm
3.00 ~ 29.99 mS/cm
30.0 ~ 200.0 mS/cm
  500.0 mS/cm ±îÁöactual (*) Conductivity
0.00 ~ 14.99 ppm
15.0 ~ 149.9 ppm
150 ~ 1499 ppm
1.50 ~ 14.99 g/L
15.0 ~ 100.0 g/L
400.0 g/L ±îÁö actual (*) TDS
(with 0.80 factor)
0.0 to 400.0 % 0.0 to 60.0°C
ÃÖ¼ÒÃøÁ¤´ÜÀ§ 0.01 µS/cm (from 0.00 ~ 29.99 µS/cm)
0.1 µS/cm (from 30.0 ~ 299.9 µS/cm)
1 µS/cm (from 300 ~ 2999 µS/cm)
0.01 mS/cm (from 3.00 ~ 29.99 mS/cm)
0.1 mS/cm ( 30.0 mS/cmÀÌ»ó)
0.01 ppm (from 0.00 ~ 14.99 ppm)
0.1 ppm (from 15.0 ~ 149.9 ppm)
1 ppm (from 150 ~ 1499 ppm)
0.01 g/L (from 1.50 ~ 14.99 g/L)
0.1 g/L ( 15.0 g/LÀÌ»ó)
0.1 % 0.1°C
Á¤È®µµ
(@ 20°C/68°F)
±1% of reading
± (0.05 µS/cm or 1 digit, whichever greater)
±1% of reading
± (0.03 ppm or 1 digit, whichever greater)
±1% of reading ±0.4°C
Typical EMC Deviation ±1% of reading ±1% of reading ±1% of reading ±0.1 °C
º¸Á¤ 1 point with 6 memorized buffers:
84, 1413 ,5000,12880, 80000 or 111800 µS/cm
1 point
with HI 7037 buffer
(optional)
2 points
at 0 and 50°C
(plus ±1°C adjustment)
¿Âµµ º¸Á¤ Automatic or Manual from 0 to 60°C (can be disabled to measure actual conductivity)
Temp. Coefficient 0.00 to 6.00 %/°C (for EC and TDS only) Default value is 1.90%/°C
TDS Factor 0.40 to 0.80 (Ãʱ⼳Á¤Ä¡=0.50)
ÇÁ·Îºê HI 76309 4-ring probe, K=1 nominal and built-in temperature sensor (included)
Àü¿ø°ø±Þ 4x1.5V AA (Æ÷ÇÔ), or 12 VDC ¾îµªÅÍ
ÀÚµ¿ ²¨Áü 5 ºÐÈÄ¿¡ ÀÚµ¿À¸·Î ²¨Áü
Casing IP 67
»ç¿ëȯ°æ 32 to 122°F (0 to 50°C); RH 100%
±Ô°Ý 7.7 x 3.1 x 2.4" (196 x 80 x 60 mm)
¹«°Ô 18 oz (500 g)
(*) Actual conductivity (or TDS) is the non-temperature compensated conductivity (or TDS) value of a solution.

      Å©°Ôº¸±â

 HI 933300

*ÈÞ´ë¿ë ¸¶ÀÌÅ©·Î ÇÁ·Î¼¼¼­, ATC Àüµµµµ ¹ÌÅÍ
*ÇÁ¸°ÅÍ¿Í µ¥ÀÌÅÍ ±â·Ï±â ³»Àå
*ÀÚµ¿º¸Á¤ ±â´É
*PC¿¡ ¿¬°áÇÏ¿© µ¥ÀÌÅ͸¦ ºí·¯µéÀÌ¸ç ±×·¡ÇÁ ÀÛ¾÷°ú ±âŸ ÀÛ¾÷À» ÇàÇÒ ¼ö ÀÖ´Ù.
*ÁÖ¹®Çϱâ

 

 

 

  ÃøÁ¤¹üÀ§:          µS/cm     0.0 ~ 150.0 µS/cm (µmho / cm)
                     µS/cm     0 ~ 1500 µS/cm (µmho / cm)
                     mS/cm     0.00 ~ 15.00 mS/cm (mmho / cm)
                     mS/cm     0.00 ~ 199.9 mS/cm (mmho / cm)
                     °C        0.0 ~ 60.0°C
  ÃÖ¼ÒÃøÁ¤´ÜÀ§:     µS/mS/°C  0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm, 0.1°C
  Á¤È®µµ:             ±1% Full Scale; ±0.5°C
  º¸Á¤:                0,84,1.413,12.880 & 80.000 µS/c¿¡¼­ ÇÑÆ÷ÀÎÆ® ÀÚµ¿ º¸Á¤
  ¿Âµµ º¸Á¤:           Auto 0 to 60°C with a variable ß from 0.0 to 3.0%/°C
  4-Ring ÇÁ·Îºê:        HI 76302W detachable with 1m cable (Æ÷ÇÔ)
  ÇÁ¸°ÅÍ:               Low-power impact type belt, using non-fading paper
  ±â·Ï ½Ã°£ ÀÎÅ͹ú:     1,2,5,10,15,30,60,120 & 180ºÐ Áß¿¡¼­ ¼±ÅÃ
º£Å͸®: 4 x 1.5V; 500 hours with 60 minute intervals Power socket for 12VDC supply »ç¿ëȯ°æ: 32 to 122°F (0 to 50°C) ¹«°Ô: 15 oz. (425g) ±Ô°Ý: 7.7 x 3.1 x 2.2" (196 x 80 x 57mm)

     Å©°Ôº¸±â

 HI 933301

*ÇÁ¸°ÅÍ¿Í ÀÚµ¿ ¿Âµµ º¸Á¤ ±â´ÉÀ» °®Ãá ÈÞ´ë¿ë ¸¶ÀÌÅ©·Î ÇÁ·Î¼¼¼­ Àüµµµµ ÃøÁ¤°è
*Á¤È®µµ°¡ ¶Ù¾î³ª´Ù.
*ÁÖ¹®Çϱâ

 

 

 

  ÃøÁ¤¹üÀ§:      µS/cm     0.0 ~ 150.0 µS/cm (µmho / cm)
                 µS/cm     0 ~ 1500 µS/cm (µmho / cm)
                 mS/cm     0.00 ~ 15.00 mS/cm (mmho / cm)
                 mS/cm     0.00 ~ 199.9 mS/cm (mmho / cm)
                 °C        0.0 ~ 60.0°C
  ÃÖ¼ÒÃøÁ¤´ÜÀ§:  µS/mS/°C  0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm, 0.1°C
  Á¤È®µµ:             ±1% Full Scale; ±0.5°C
  º¸Á¤:                 0,84,1.413,12.880 & 80.000 µS/c¿¡¼­ ÀÚµ¿ ÇÑÆ÷ÀÎÆ® º¸Á¤
  ¿Âµµ º¸Á¤:            Auto 0 ~ 60°C with a variable ß from 0.0 ~ 3.0%/°C
  4-Ring ÇÁ·Îºê:        HI 76302W detachable with 1m cable (included)
  ÇÁ¸°ÅÍ:               Low-power impact type belt, using non-fading paper
  ±â·Ï½Ã°£ ÀÎÅ͹ú:      1,2,5,10,15,30,60,120 & 180 ºÐ Áß¿¡¼­ ¼±ÅÃ
º£Å͸®: 4 x 1.5V; 500 hours with 60 minute intervals Power socket for 12VDC supply »ç¿ëȯ°æ: 32 ~ 122°F (0 ~ 50°C) ¹«°Ô: 15 oz. (425g) ±Ô°Ý: 7.7 x 3.1 x 2.2" (196 x 80 x 57mm)